Sound system measurement glossary
The words that come up when measuring and tuning a sound system, each in a sentence or two, with a link to the guide that explains it properly.
Updated 17 November 2026
- Acoustic center
- The point a loudspeaker's sound appears to come from. For timing, distances are measured from it, not from the front of the box.
- Arrival time
- When the direct sound reaches the microphone, after the reference: the peak of the impulse response. About 2.9 ms per meter.
- ASIO
- A low-latency audio driver standard for Windows, supplied by the interface maker.
- Averaging
- Combining successive measurement frames to separate the system's response from noise. Deeper averaging is steadier but slower to react.
- Banding
- Summing spectrum energy into fractional-octave bands, from 1/1 to 1/48 octave, as an RTA does.
- Calibration
- Linking an input's dBFS to dB SPL with an acoustic calibrator. See microphone calibration.
- Coherence (γ²)
- The share of the measurement signal explained linearly by the reference, from 0 to 1: how far to trust a reading at each frequency. See coherence explained.
- Comb filter
- The regular row of notches caused by two copies of a signal arriving at different times. Two arrivals 1 ms apart notch at 500 Hz, 1.5 kHz, 2.5 kHz and so on.
- Complex averaging
- Vector averaging of the transfer function. It rejects noise unrelated to the reference and reads low where coherence is low.
- Crossover
- The frequency range where two sources or two ways of a loudspeaker share the signal. See how to align subs and tops.
- dBFS
- Decibels relative to the converter's full scale. 0 dBFS is the largest value the converter can represent.
- dB SPL
- Sound pressure level in decibels relative to 20 µPa. 94 dB SPL is 1 Pa.
- Delay (inserted)
- The delay the analyzer applies to the reference so it lines up with the arrival at the microphone. Without it the phase is unreadable.
- Dual-channel measurement
- Comparing two signals, the reference sent to the system and the microphone, so the result shows the system regardless of the program.
- EDT
- Early decay time: the first 10 dB of a room's decay, scaled to 60 dB. Closer to perceived reverberance than RT60.
- ETC
- Energy-time curve: the envelope of the impulse response in dB. The usual view for reading arrivals and decay.
- FFT
- Fast Fourier Transform: turns a block of samples into a spectrum. Its size sets the frequency resolution and the time window. See FFT size and time windows.
- Group delay
- The arrival time of each frequency, from the slope of the phase, in milliseconds.
- Impulse response
- The system's output for an ideal click: the transfer function seen in time. See how to measure a room.
- Leq
- Equivalent continuous level: the steady level with the same energy as a varying one over a stated time. Most level limits are written as an Leq. See SPL monitoring.
- Magnitude
- The gain of the system at each frequency, in dB relative to the reference.
- MTW (multi-time window)
- A transfer function analysis that measures each octave with a time window suited to it: long windows at low frequencies, short ones at high. PA Trace's version is MTW++.
- Narrowband
- A spectrum shown at the FFT's own resolution, without banding.
- Phase
- The time shift of each frequency, in degrees of its own cycle. 360° is one full cycle.
- Pink noise
- Random noise with equal energy per octave. It reads flat on a banded RTA and is the standard test signal.
- Polar averaging
- Magnitude from the averaged powers of the two signals. It reads the level a listener hears, noise included.
- Polarity
- The sign of a signal. A reversed source pushes where the others pull. See how to check polarity.
- Reference
- The signal the system under test receives, taken as the transfer function's input. See measurement setup.
- Room mode
- A low-frequency resonance of a room, strong at some positions and weak at others.
- RT60
- Reverberation time: how long sound takes to decay by 60 dB, usually extrapolated from a 20 dB (T20) or 30 dB (T30) range.
- RTA
- Real-time analyzer: the spectrum of a single signal, without a reference.
- Schroeder curve
- The backward-integrated energy decay of an impulse response, from which reverberation times are read.
- Smoothing
- Averaging each point with its neighbors over a fractional octave, for display only.
- STI
- Speech Transmission Index (IEC 60268-16), from 0 to 1: how intelligible speech will be at a position.
- Target curve
- The response a system is tuned toward, usually with a tolerance band. See how to EQ a PA system.
- Trace
- A stored copy of a measurement's result, kept for comparison, averaging and documentation.
- Transfer function
- H(f) = Y(f) / X(f): what a system does to each frequency, in level and in time. See transfer function explained.
- Weighting (frequency)
- A curve applied to a measurement to follow the ear or a standard, such as A or C.
- Window (FFT)
- The fade applied to each analysis block, such as Hann; also the block's length in time.
- Wind Lock
- PA Trace's alignment of each measurement frame to the running average before averaging, so wind does not wash out the top octaves.
Related guides
- Transfer function measurement, explained Magnitude, phase, coherence and the impulse response: what they are and how to read them.
- Coherence explained What the coherence trace means, what each pattern of low coherence points to, and how to raise it.
- Measurement setup Microphone, interface, where to take the reference, and the levels that make a measurement trustworthy.
- Room acoustics: RT60 and STI Read the impulse response, measure reverberation time, clarity and speech intelligibility, and find the surface behind a reflection.